{"id":7218,"date":"2023-09-11T10:30:50","date_gmt":"2023-09-11T03:30:50","guid":{"rendered":"https:\/\/kitcha.co.th\/?post_type=product&#038;p=7218"},"modified":"2023-11-21T08:58:17","modified_gmt":"2023-11-21T01:58:17","slug":"waeco-asc-6100g-h-%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%b7%e0%b9%88%e0%b8%ad%e0%b8%87%e0%b8%94%e0%b8%b9%e0%b8%94%e0%b8%81%e0%b8%b1%e0%b8%81%e0%b9%80%e0%b8%81%e0%b9%87%e0%b8%9a-%e0%b8%9f%e0%b8%ad%e0%b8%81","status":"publish","type":"product","link":"https:\/\/kitcha.co.th\/en\/shop\/waeco-asc-6100g-h-%E0%B9%80%E0%B8%84%E0%B8%A3%E0%B8%AD%E0%B8%87%E0%B8%94%E0%B8%94%E0%B8%81%E0%B8%81%E0%B9%80%E0%B8%81%E0%B8%9A-%E0%B8%9F%E0%B8%AD%E0%B8%81\/","title":{"rendered":"WAECO ASC 6100G-H"},"content":{"rendered":"<h3><b><span data-contrast=\"none\">WAECO ASC6100G<\/span><\/b><\/h3>\n<ul>\n<ul>\n<p><span data-contrast=\"none\">Air conditioning service unit, triple certified, 9 kg<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335551550&quot;:2,&quot;335551620&quot;:2,&quot;335559739&quot;:150,&quot;335559740&quot;:240}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">Entry-level triple certified A\/C service unit. Automatic refrigerant recycling, UV and oil management. Convenient software update via USB port. Thanks to a new modular concept, basic ASC can be turned to a service unit for either R134a, R1234yf or R513A refrigerants, depending on the appropriate connection kit, for one refrigerant type of your choice (sold separately).<\/span><span data-ccp-props=\"{&quot;201341983&quot;:2,&quot;335551550&quot;:2,&quot;335551620&quot;:2,&quot;335559739&quot;:0,&quot;335559740&quot;:336}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"none\">&#8230;AND MORE<\/span><\/b><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:240}\">\u00a0<\/span><\/p>\n<ul>\n<p><span data-contrast=\"none\">\u2022\u00a0Entry-level A\/C service unit \u2013 competitive price<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:75,&quot;335559740&quot;:240,&quot;335559991&quot;:312}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">\u2022\u00a0Humidity-free storage and feeding system for fresh oil and UV additive supplied with the associated connection kit (sold separately)<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:75,&quot;335559740&quot;:240,&quot;335559991&quot;:312}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">\u2022\u00a0Automatic refrigerant recycling, UV and oil management controlled by load cell<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:75,&quot;335559740&quot;:240,&quot;335559991&quot;:312}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">\u2022\u00a0USB interface for convenient software update or export of service data<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:75,&quot;335559740&quot;:240,&quot;335559991&quot;:312}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">\u2022\u00a0Purity of the recovered refrigerant complies with the SAE J 2099 standard<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:75,&quot;335559740&quot;:240,&quot;335559991&quot;:312}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">\u2022\u00a0Minimum 95 % refrigerant recycling rate<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:75,&quot;335559740&quot;:240,&quot;335559991&quot;:312}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">\u2022\u00a0Soft graphic display \u2013 can also display special characters<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:75,&quot;335559740&quot;:240,&quot;335559991&quot;:312}\">\u00a0<\/span>\n<\/ul>\n<\/ul>\n<p><b><span data-contrast=\"none\">THE PERFECT ENTRY-LEVEL A\/C SERVICE UNIT<\/span><\/b><span data-ccp-props=\"\n{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335551550&quot;:2,&quot;335551620&quot;:2,&quot;335559738&quot;:300,&quot;335559739&quot;:150,&quot;335559740&quot;:240}\">\u00a0<\/span><\/p>\n<ul>\n<span data-contrast=\"none\">The low investment ASC 6100 G is ideal for anyone who has just started to provide A\/C service on R134a, R1234yf or R513A air conditioners. Offering you all the features required to work safely, it also saves you time by performing all service processes automatically. The purity of the recovered refrigerant complies with the SAE J 2099 standard. Expecting more orders in the future? You can easily upgrade your service unit at a later date \u2013 add a heat belt for the charging cylinder, or our humidity-free storage and feeding system for fresh oil and UV additive. A USB port for convenient software updates and soft graphic display which can display special characters are already included.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335551550&quot;:2,&quot;335551620&quot;:2,&quot;335559738&quot;:0,&quot;335559739&quot;:150,&quot;335559740&quot;:240}\">\u00a0<\/span>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><b><span data-contrast=\"auto\">SPECIFICATIONS<\/span><\/b><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<ul>\n<table style=\"height: 1996px\" width=\"895\" data-tablestyle=\"MsoTableGrid\" data-tablelook=\"1184\">\n<tbody>\n<tr>\n<td data-celllook=\"0\"><b><span data-contrast=\"none\">GENERAL<\/span><\/b><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<td data-celllook=\"0\"><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0SKU number<\/td>\n<td data-celllook=\"0\">9103303104<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0For Refrigerant<\/td>\n<td data-celllook=\"0\">R1234yf, R134a, R513a<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Input voltage (AC)<\/td>\n<td data-celllook=\"0\">220-240\u202fV<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Input frequency<\/td>\n<td data-celllook=\"0\"><span data-contrast=\"auto\">50\/60\u202fHz<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\"><b><span data-contrast=\"none\">RECOVERY \/ RECYCLING<\/span><\/b><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<td data-celllook=\"0\"><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Purity of recovered refrigerant (SAE J 2099)<\/td>\n<td data-celllook=\"0\">Yes<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Refrigerant recovery rate<\/td>\n<td data-celllook=\"0\"><span data-contrast=\"auto\">30.00\u202fkg\/h<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Vacuum pump capacity<\/td>\n<td data-celllook=\"0\">5 cars\/h<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Performance of the hermetic compressor<\/td>\n<td data-celllook=\"0\">0.32\u202fkW<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Dry filter capacity<\/td>\n<td data-celllook=\"0\">150.00\u202fkg<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Refrigerant recycling rate<\/td>\n<td data-celllook=\"0\">Min. 95 %<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Can be used as diagnosis tool<\/td>\n<td data-celllook=\"0\">No<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0CHARGING<\/td>\n<td data-celllook=\"0\"><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Refrigerant Capacity<\/td>\n<td data-celllook=\"0\"><span data-contrast=\"auto\">11.00\u202fkg<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\"><b><span data-contrast=\"none\">PROCESSES<\/span><\/b><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<td data-celllook=\"0\"><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Refrigerant analysis<\/td>\n<td data-celllook=\"0\">No<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Recovery\/recycling<\/td>\n<td data-celllook=\"0\">Automatic\u202f\/ Electronic<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Purging of non-condensable gases<\/td>\n<td data-celllook=\"0\">Automatic\u202f\/ Electronic<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Purging of used oil<\/td>\n<td data-celllook=\"0\"><span data-contrast=\"auto\">Automatic\u202f\/ Electronic<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Evacuation<\/td>\n<td data-celllook=\"0\">Automatic\u202f\/ Electronic<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Vacuum check<\/td>\n<td data-celllook=\"0\">Automatic \/ Electronic<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Nitrogen leak check<\/td>\n<td data-celllook=\"0\">No<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Injection of leak detection additive<\/td>\n<td data-celllook=\"0\">Automatic\u202f\/ Electronic<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Injection of oil into the A\/C system<\/td>\n<td data-celllook=\"0\">Automatic\u202f\/ Electronic<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Refrigerant charging<\/td>\n<td data-celllook=\"0\"><span data-contrast=\"auto\">Automatic\u202f\/ Electronic<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\"><b><span data-contrast=\"none\">CONTROL PANEL<\/span><\/b><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<td data-celllook=\"0\"><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0USB Port<\/td>\n<td data-celllook=\"0\">Yes<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0High\/low pressure indicated by<\/td>\n<td data-celllook=\"0\">Manometer<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Vacuum indicated by<\/td>\n<td data-celllook=\"0\">Display<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Total process control indicated by<\/td>\n<td data-celllook=\"0\">Display<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Option to set the evacuation time<\/td>\n<td data-celllook=\"0\">Yes<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Protocol print-out possible<\/td>\n<td data-celllook=\"0\"><span data-contrast=\"auto\">No<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\"><b><span data-contrast=\"none\">DIMENSION<\/span><\/b><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<td data-celllook=\"0\"><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Depth x Height x Width<\/td>\n<td data-celllook=\"0\">600 x 1,040 x 600 mm.<\/td>\n<\/tr>\n<tr>\n<td data-celllook=\"0\">\u00a0 \u00a0 \u00a0Net Weight<\/td>\n<td data-celllook=\"0\"><span data-contrast=\"auto\">90 Kg.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><\/h3>\n","protected":false},"excerpt":{"rendered":"<p>WAECO ASC6100G Air conditioning service unit, triple certified, 9 kg\u00a0 Entry-level triple certified A\/C service unit. Automatic refrigerant recycling, UV and oil management. Convenient software update via USB port. Thanks to a new modular concept, basic ASC can be turned to a service unit for either R134a, R1234yf or R513A refrigerants, depending on the appropriate<\/p>\n","protected":false},"featured_media":7205,"template":"","meta":{"om_disable_all_campaigns":false,"inline_featured_image":false},"product_brand":[],"product_cat":[104,605,91,97],"product_tag":[],"class_list":{"0":"post-7218","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-all-products-en","7":"product_cat-waeco-en","8":"product_cat-air-conditioning-en","9":"product_cat-recovery-recharging-station-en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/kitcha.co.th\/en\/wp-json\/wp\/v2\/product\/7218","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kitcha.co.th\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/kitcha.co.th\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kitcha.co.th\/en\/wp-json\/wp\/v2\/media\/7205"}],"wp:attachment":[{"href":"https:\/\/kitcha.co.th\/en\/wp-json\/wp\/v2\/media?parent=7218"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/kitcha.co.th\/en\/wp-json\/wp\/v2\/product_brand?post=7218"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/kitcha.co.th\/en\/wp-json\/wp\/v2\/product_cat?post=7218"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/kitcha.co.th\/en\/wp-json\/wp\/v2\/product_tag?post=7218"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}